冷却水温度高
High cooling water temperature
现象:站控值班人员发现燃气发电机水温偏高,相关人员随即赴现场对发电机组进行检查,风扇等冷却系统正常,控制面板无报警。半小时之后,上位机出现该燃气发电机冷却水温度高报警, 进而造成停机。
Phenomenon: The station control duty personnel found that the water temperature of the gas generator was too high. Relevant personnel immediately went to the site to inspect the generator set. The cooling system such as the fan was normal, and there was no alarm on the control panel. Half an hour later, the upper computer triggered a high temperature alarm for the cooling water of the gas generator, resulting in a shutdown.
造成此次冷却水温度高原因分析:该燃气发电机正常运行时冷却水温度在89℃左右,当负载有较大幅度的提升时,冷却水温度随即上升,超过临界值导致报警停机。
Analysis of the reasons for the high cooling water temperature this time: When the gas generator is running normally, the cooling water temperature is around 89 ℃. When the load increases significantly, the cooling water temperature immediately rises, exceeding the critical value and causing an alarm shutdown.
其他原因分析:(1)冷却水管路存在结垢现象,导致冷却水散热不佳;(2)冷却风扇电机损坏,导致散热不佳;(3)节温器卡住或者其他原因导致未打开;(4)冷却水管路或者接头处漏水,冷却水自然损耗液位降低导致冷却水缺失;(5)冷却水温度传感器故障,导致检测结果失准。
Other reasons analysis: (1) There is scaling in the cooling water pipeline, which leads to poor heat dissipation of the cooling water; (2) The cooling fan motor is damaged, resulting in poor heat dissipation; (3) The thermostat is stuck or not opened due to other reasons; (4) Leakage at the cooling water pipeline or joint, resulting in natural loss of cooling water and a decrease in liquid level, leading to a shortage of cooling water; (5) The cooling water temperature sensor has malfunctioned, resulting in inaccurate detection results.
功率转换模块故障
Power conversion module malfunction
现象:现场燃气发电机奇才控制屏显示“逆功”故障报警停机。站控上位机发电机功率曲线在停机瞬间有一处异常跳变现象。
Phenomenon: The control screen of the on-site gas generator shows a "reverse power" fault alarm and shutdown. There is an abnormal jump phenomenon in the power curve of the generator on the station control upper computer at the moment of shutdown.
原因分析:相关人员查看现场接线柜,检测功率转换模块,4~20mA输出存在问题。经过分析,可能冲击电流导致功率转换器故障。
Cause analysis: Relevant personnel inspected the on-site wiring cabinet, tested the power conversion module, and found that there was a problem with the 4-20mA output. After analysis, it is possible that the surge current caused the power converter to malfunction.
电机控制故障
Motor control malfunction
现象:奇才控制屏显示“Motor Control Fault”故障报警信息。
Phenomenon: The Qicai control screen displays a "Motor Control Fault" fault alarm message.
原因分析:根据显示屏提示的消息,打开燃气发电机组电机控制柜,经过检查陆续排除接线松动及其他部件的损坏情况,针对IMO TDMD-X延时继电器进行检测,发现延时继电器ATR上电到指定时间后不能正常吸合,确认为延时继电器故障。更换延时继电器之后,燃气发电机正常运行。
Cause analysis: According to the message displayed on the screen, open the motor control cabinet of the gas generator set, and after inspection, gradually eliminate loose wiring and damage to other components. Conduct a test on the IMO TDMD-X delay relay and find that the ATR delay relay cannot be closed normally after being powered on for the specified time, confirming a fault in the delay relay. After replacing the delay relay, the gas generator operated normally.
其他原因分析:冷却风扇故障。由于冷却风扇长时间运转,轴承可能变形导致风扇不工作, 此种情况同样会引起电机控制故障报警。
Other cause analysis: Cooling fan malfunction. Due to prolonged operation of the cooling fan, the bearings may deform and cause the fan to malfunction, which can also trigger motor control failure alarms.
启机失败
Startup failed
现象:燃气发电机在启动怠速转动一阵子后自动停机。
Phenomenon: The gas generator automatically shuts down after idling for a while.
原因分析:(1)蓄电池电压不足以带动燃气发电机启机;(2)燃气发电机燃气管线至燃烧室之间的管路富含燃气,空气不足,不足以点火燃烧;(3)点火系统故障,如点火线圈故障,火花塞受潮,火花塞端部孔隙堵塞;(4)启动马达故障;(5)气源压力不足;(6)热备系统未投用,导致燃气发电机本体温度过低;(7)阴潮环境,应注意燃气发电机的定期热机。
Reason analysis: (1) Insufficient battery voltage to drive the gas generator to start; (2) The pipeline between the gas pipeline of the gas generator and the combustion chamber is rich in gas, and there is insufficient air to ignite combustion; (3) Ignition system malfunction, such as ignition coil failure, spark plug moisture, and blockage of spark plug end pores; (4) Start motor malfunction; (5) Insufficient gas source pressure; (6) The hot standby system has not been put into use, resulting in a low temperature of the gas generator body; (7) In cloudy and humid environments, attention should be paid to the regular heating of gas generators.
爆震
detonation
现象:现场控制屏出现“Knocking”故障报警信息。
Phenomenon: A "Knocking" fault alarm message appears on the on-site control screen.
原因分析:(1)气缸燃烧室内积碳过多,容易在积碳表面形成高温着火点;(2)点火提前角过于提前,导致点火引燃混合燃气的时间早于活塞到达上止点的时间,从而在活塞压缩冲程中压力急剧升高导致爆燃的发生。同时,爆燃产生的压力作用于活塞,影响活塞的冲程,导致爆震现象;(3)冷却水温度过高导致发动机机体温度高,散热不良,产生高温而发生爆震;(4)空燃比不正确等其他情况。
Cause analysis: (1) Excessive carbon deposition in the combustion chamber of the cylinder can easily form high-temperature ignition points on the surface of the carbon deposition; (2) The ignition advance angle is too early, resulting in the ignition of the mixed gas earlier than the time when the piston reaches the top dead center, leading to a sharp increase in pressure during the piston compression stroke and the occurrence of detonation. At the same time, the pressure generated by detonation acts on the piston, affecting its stroke and causing detonation phenomenon; (3) Excessive cooling water temperature leads to high engine body temperature and poor heat dissipation, resulting in high temperature and detonation; (4) Incorrect air-fuel ratio and other situations.
机组不能正常带载
The crew cannot carry the load normally
现象:机组在切机加载过程中不能同步并机,无法带载运行。
Phenomenon: The unit cannot synchronize and operate with load during the cutting and loading process.
原因分析:(1)燃气发电机输出空气开关是否闭合状态;(2)发电机出口断路器系统GCB 复位按钮是否弹出,如果弹出,直接按压,然后再进行同步并机加载。
Reason analysis: (1) Whether the output air switch of the gas generator is closed; (2) Does the GCB reset button of the generator outlet circuit breaker system pop up? If it pops up, press it directly and then perform synchronous parallel loading.
低油压报警
Low oil pressure alarm
现象:站控上位机系统出现燃气发电机低油压报警,参照Wilson PG345B3型燃气发电机正常运行时油压基本处于4.5MPa左右。
Phenomenon: The station control upper computer system has a low oil pressure alarm for the gas generator. Referring to the normal operation of Wilson PG345B3 gas generator, the oil pressure is basically around 4.5MPa.
原因分析:(1)机油管路渗漏导致机油压力降低;(2)机油泵密封损坏或者机械损坏,导致 机油泄漏;(3)机油压力探头损坏,数据传导出错。机油压力探头安装在燃气发电机机油滤芯附近,在震动环境下易损坏,可以考虑将机油压力探头移出本体,架设在一个相对震动不大的地方,以延长探头的使用寿命,减少故障发生。
Cause analysis: (1) Leakage in the oil pipeline leads to a decrease in oil pressure; (2) Oil pump seal damage or mechanical damage, resulting in oil leakage; (3) The oil pressure probe is damaged and the data transmission is incorrect. The oil pressure probe is installed near the oil filter element of the gas generator, which is prone to damage in a vibrating environment. It can be considered to remove the oil pressure probe from the body and install it in a relatively low vibration area to extend the service life of the probe and reduce the occurrence of faults.
防范措施
preventive measures
加强日常巡检
Strengthen daily inspections
每日定点巡检,重点检查机组的各项参数,上位机系统可设置报警值。重点检查燃气发电机 的转速、频率、出口电压、功率、机油压力、冷却水温度以及蓄电池电压等参数。现场查看燃气发电机冷却风扇的运转情况,冷却水管路和机油管路的渗漏情况,同时查看机油液位和冷却水液位。现场辨听燃气发电机运行时有无异常声响。手持测温枪对冷却风扇电机壳和气缸进行温度检测。
Daily fixed-point inspection, focusing on checking various parameters of the unit, and the upper computer system can set alarm values. Focus on checking parameters such as speed, frequency, outlet voltage, power, oil pressure, cooling water temperature, and battery voltage of the gas generator. On site inspection of the operation of the cooling fan of the gas generator, leakage of the cooling water pipeline and oil pipeline, as well as checking the oil and cooling water levels. Listen for any abnormal sounds during the operation of the gas generator on site. Use a handheld thermometer to measure the temperature of the cooling fan motor casing and cylinder.
维护保养
maintenance
参考Wilson厂商提供的燃气发电机维保手册,结合现场实际运营经验,制定并严格执行合规的维保规程。维保级别一般有首保,500h维保,1000h维保,2000h维保,4000h维保,8000h维保以及中修和大修维保。不同的维保级别对应不同的项目检查和部件更换。维保要做到全面,重点检查气门间隙,气门凸出量调整,曲轴箱呼吸器清洁,火花塞检查,正时传感器清洁,延时继电器和其他电气元件的检查,水路和油路的检查等。同时,控制系统接线松紧度以及各传感器探头的检查校准。
Based on the maintenance manual provided by Wilson manufacturer for gas generators and combined with on-site operational experience, develop and strictly implement compliant maintenance procedures. The maintenance levels generally include first maintenance, 500h maintenance, 1000h maintenance, 2000h maintenance, 4000h maintenance, 8000h maintenance, as well as medium and major maintenance. Different maintenance levels correspond to different project inspections and component replacements. Maintenance should be comprehensive, with a focus on checking valve clearances, adjusting valve protrusion, cleaning crankcase respirators, checking spark plugs, cleaning timing sensors, checking delay relays and other electrical components, and inspecting water and oil circuits. At the same time, check and calibrate the tightness of the control system wiring and the probes of each sensor.
意外事件记录分析
Analysis of Unexpected Event Records
生产运营过程中难免会遇到燃气发电机意外停机现象,对故障问题的精准判断直接关系到生 产经营活动的恢复快慢。在燃气发电机组运行过程中,注重常见故障和其他故障的分类总结、归类,制定一套事件应急处置卡,针对不同的故障类型编制不同的操作要求及部件更换。经过长期的意外停机事件积累,对于燃气发电机的故障处理能力会有明显的提升。
During the production and operation process, it is inevitable to encounter unexpected shutdowns of gas generators, and accurate diagnosis of the fault directly affects the speed of recovery of production and operation activities. During the operation of gas generator sets, attention should be paid to the classification and summary of common and other faults, and a set of emergency response cards should be developed. Different operation requirements and component replacement should be formulated for different types of faults. After long-term accumulation of unexpected shutdown events, the fault handling ability of gas generators will be significantly improved.
加强人员培训考核加强站场相关人员对燃气发电机的掌握,逐步提高意外停机事件的应急响应机制和处理能力。通过岗位练兵和培训考核,保证专业人员对燃气发电机的熟悉掌握。同时,可以定期举办人员交流,分享彼此燃气发电机运维经验。
Strengthen personnel training and assessment, enhance the mastery of gas generators by station personnel, and gradually improve the emergency response mechanism and handling capabilities for unexpected shutdown events. Through job training and assessment, ensure that professionals are familiar with and proficient in gas generators. At the same time, regular personnel exchanges can be held to share each other's experience in gas generator operation and maintenance.
其他设备管理提升方面
Improvement in other device management aspects
针对站场燃气发电机的实际情况,鼓励相关人员提升设备管理能力。由于Wilson燃气发电机的监测系统并不完善,可以增设各种传感器探头完善相关的监测功能,比如缸温缸压,废气温度及燃烧点火时间等。同时,可以开发专用软件用于监测燃气发电机其他参数,比如维保参数,部件使用寿命参数等,可以合理有效地加强设备的管理水平,降低故障的发生。
Encourage relevant personnel to improve their equipment management capabilities based on the actual situation of gas generators in the station. Due to the incomplete monitoring system of Wilson gas generators, various sensor probes can be added to improve related monitoring functions, such as cylinder temperature and pressure, exhaust gas temperature, and combustion ignition time. At the same time, specialized software can be developed to monitor other parameters of gas generators, such as maintenance parameters, component service life parameters, etc., which can effectively strengthen the management level of equipment and reduce the occurrence of faults.
结束语
Conclusion
综上所述,导致Wilson燃气发电机运行故障有多种原因,为了减少故障问题的发生,需要加强相关人员的培训,严格执行巡检要求和维护保养规程。同时,善于总结各类故障问题,加强故障诊断能力,保障燃气发电机的安全平稳运行。
In summary, there are multiple reasons for the operation failure of Wilson gas generators. In order to reduce the occurrence of failure problems, it is necessary to strengthen the training of relevant personnel, strictly implement inspection requirements and maintenance procedures. At the same time, being good at summarizing various fault problems, strengthening fault diagnosis capabilities, and ensuring the safe and stable operation of gas generators.
本文由 燃气发电机组配件 友情奉献.更多有关的知识请点击 https://www.huannengpower.cn/ 真诚的态度.为您提供为全面的服务.更多有关的知识我们将会陆续向大家奉献.敬请期待.